CS75-24 |
AC-DC Converter > C-series > CS75-24 |
|
|
|
|
|
|
|
1 |
AC 170 ~ 264V or DC 240 ~ 340V |
24V@3.20A |
76.80W |
200mVp-p |
85% |
CS75-24 |
Total power : 75 Watts
Input voltages : AC 90~132V / AC 170~264(or DC240~340V)
#of outputs : Single output
- CE Marking
- Small, Compact Size
- Surface mounting technology
- High efficiency
- Universal input
- Built-in EMI filter
- Inrush current limit
- Adjustable output voltage
- Output over current protection
- Output over voltage protection
- Over temperature protection
- Low output ripple & noise
- Isolated output
- 2 Years warranty
- Operating temperature range ......... -10℃ ~ 60℃
- Storage temperature range ............ -20℃ ~ 70℃
- Humidity ......................................... 20% ~ 90%RH
- Vibration ......................................... 10~55Hz at 2G 3minutes period
- Impact ............................................ 20G for 11ms, once on each X,Y and Z-axis
- Cooling method .............................. Covection
- MTBF(MIL-HDBK-217F) ................ 1.8 x 105hrs
- Safety Approved ............................ CE (EN60950-1) through TUV
- Noise .............................................. meets CISPR22-B / FCC class B
INPUT
- Voltage ......................................... CS75L : AC90V - 132V (note1) CS75 : AC170V - 264V (or DC 240 - 340V)(note1)
- Current ......................................... 1.7A max. (CS75L) / 0.9A Max. (CS75)
- Frequency .................................... 47 - 440Hz max. (50~60Hz typ.)
- Efficiency ..................................... 77 - 86% typ.
- Inrush current (at cold start) ........ 20A max. @ 110VAC. (CS75L) / 40A max. @ 220Vac (CS75)
- Leakage current ........................... 0.5mA max. @ 110VAC (CS75L) / 0.75mA max. @220Vac (CS75)
OUTPUT
- Voltage tolerance ........................ ±10% typ.
- Ripple and noise ......................... ±1% max.
- Line regulation ............................ ±1% max.
- Load regulation ........................... ±1% max.
- Dynamic load regulation ............. ±3% max.
- Temperature drift ........................ ±1% typ.
- Rising time .................................. 100ms max.
- Holding time ................................ 17ms min.
PROTECTION CIRCUIT
- Over current protection ............... Work Over 105% of rating (Recovers Automatically)
- Over voltage protection ............... Work at 115~140% of rating (Latch-up mode)
- Over temperature protection ....... 80°C min.
ELECTRICALLY ISOLATED
- Input - Output .............................. AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG .................................... AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ................................. AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min.
(NOTE : For cases where conformance to various safety specs (CE, etc) are required, input voltage and frequency range will be 100-240VAC, 50/60Hz.)
|