INPUT
- Input range ........................................... DC 36V - 75V
- Efficiency ............................................... 87% - 88% typ.
- Remote on/off ...................................... Negative
OUTPUT
- Voltage tolerance .............................. ±2%
- Line Regulation ................................. ±0.5%
- Load Regulation ............................... ±0.5%
- Ripple & Noise,Vpk-pk ..................... < 50mV
- Dynamic response ........................... < 100mV (50%->75%, 75%->50%, 0.1A/us)
- Sense range ........................................ +10%
- Trim range ........................................... -20% ~ +10%
PROTECTION CIRCUIT
- Over current protection ..................... Over 105% of rating (Auto-recovery)
- Over voltage protection ..................... About 125% of rating (Latch-up)
- Input under voltage protection ........ DC 32V (Auto-recovery)
- Input over voltage protection ........... DC 80V (Auto-recovery)
- Over temperature protection ...........125℃ (Auto-recovery)
ELECTRICALLY ISOLATED
- Input - Output ..................................... DC 1500V
NOTE 1. Ripple & noise is tested / specified over a 20MHz bandwidth and may be reduced with external filtering.