INPUT
- Voltage .......................................... AC85~264V (or DC 110~340V)
- Current .......................................... 0.31A max. @ 110VAC / 0.16A max. @ 220VAC
- Frequency .................................... 47~440Hz max. (50~60Hz typ.)
- Efficiency ...................................... 70% min.
- Inrush current (at cold start) ..... 30A max. @ 110VAC. / 60A max. @ 220VAC
- Leakage current ......................... 0.5mA max. @ 110VAC / 0.75mA max. @ 220VAC
OUTPUT
- Voltage tolerance ....................... ±10%% typ.
- Ripple and noise ........................ 1% max.
- Line regulation ............................ ±1 max. @Output 1,3/ ±2% max. @ Output2
- Load regulation ........................... ±1 max. @Output 1,3/ ±2% max. @ Output2
- Dynamic load regulation ........... ±3 max. @ Output1
- Temperature drift ........................ ±1% typ.
- Rising time ................................... 100ms max.
- Holding time ................................. 10ms min
PROTECTION
- Output short circuit protection ..... Work at over 105% of rating & recovers automatically
ELECTRICALLY ISOLATED
- Input - Output ............................. AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG .................................... AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ................................. AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min.